User Tools

Site Tools


importance_of_unit_system

This is an old revision of the document!


Unit Systems

Scan&Solve relies on the unit system chosen when a model is created. The unit system entered into Rhino is used by Scan&Solve to interpret the geometry when restraints and loads are applied to the model.

Entering an incorrect unit system

If an incorrect unit system is supplied to Rhino when the model is created, the loads and thus danger level applied to the model will likely be significantly different than expected.

In the following example, a beam is restrained on the left end boundary and has a 1000 N load applied on the right end boundary which causes bending of the beam.

In the first image, the model was created by choosing the millimeters unit system. The danger level of the beam failing is very high.

However, if the beam was intended to be modeled in meters, the result is quite different. Note that in both cases, Rhino shows the dimension of the beam to be 10.00.

Entering Loads in Different Units

Scan&Solve can accept loads in different units than the unit system chosen for the geometric model.

importance_of_unit_system.1433970020.txt.gz ยท Last modified: 2015/06/10 15:00 by will